55 Watt UV Quartz Sleeve
Cracked sleeve, wet lamp, dead ballast. Keep a spare.
The fused quartz tube that keeps the lamp dry inside the chamber and lets the UV through, 24.5 mm by 940 mm with one open end, supplied with two O-rings. It rarely wears out but it does break, usually during a lamp change, and the unit cannot run without it. Clean it every six months; replace it when it is cracked, etched or clouded.
Why it matters
Ordinary glass blocks UV-C. Fused quartz passes over 90% of it, which is why the sleeve is quartz and why a clouded or scaled sleeve quietly halves the dose. A cracked one lets water reach the lamp and the ballast, and that is a lamp, a ballast and a sleeve to replace instead of one.
Cleaning and changing
Every six months: power off, gland nut off, lamp out, then draw the sleeve out carefully and wipe it with a soft cloth and white vinegar or alcohol. Hard water leaves a scale film that vinegar lifts. Fit the new O-rings whenever the sleeve comes out; they are what seals the chamber.
Before you buy.
Goes with it.
Whole shop
Yearly55 Watt UV Lamp, Replacement
The only part that wears. Once a year, whether it looks tired or not.

55 Watt UV Ballast
The electronics. Indicator on the front, surge protector recommended.

Free courier55 Watt UV Steriliser, Stainless Steel
Bacteria, viruses and cysts, stopped by light, at 2 720 litres an hour.